Do you have a question about the Vyaire Avea and is the answer not in the manual?
Type | Ventilator |
---|---|
Pressure Range | 0 to 100 cmH2O |
Power Requirements | 100-240 VAC, 50/60 Hz |
Compliance Monitoring | Yes |
Patient Type | Adult and Pediatric |
Ventilation Modes | SIMV, CPAP |
Respiratory Rate | 1 to 150 breaths per minute |
FiO2 Range | 21 to 100% |
PEEP/CPAP | 0 to 20 cmH2O |
Inspiratory Time | 0.1-5 seconds |
Monitored Parameters | FiO2 |
Alarms | High pressure, Low pressure, Apnea |
Screen Size | 15 inches |
Connectivity | Ethernet |
Pressure Support Range | 0-40 cmH2O |
Describes the primary user interface interaction methods on the Avea ventilator.
Explains how to access and select ventilation modes and breath types.
Guides users on accessing and configuring advanced ventilation parameters.
Details the process of configuring patient-specific alarm limits for safety.
Introduces the two basic breath types: mandatory and demand breaths.
Lists and describes the five types of mandatory breaths the Avea ventilator can deliver.
Explains patient-triggered breaths, PSV, and spontaneous breaths.
Details the Avea's intra-breath demand system in volume-controlled modes.
Describes Synchronized Intermittent Mandatory Ventilation with volume control.
Explains pressure-controlled breaths and the Pressure Assist Control (A/C) mode.
Details Synchronized Intermittent Mandatory Ventilation with pressure control.
Explains Time Cycled Pressure Limited (TCPL) ventilation modes.
Describes TCPL SIMV mode, its controls, and features.
Explains Pressure Regulated Volume Control (PRVC) and its operation.
Details the PRVC Assist Control (A/C) mode and its controls.
Describes PRVC SIMV mode, its controls, and features.
Explains Airway Pressure Release Ventilation (APRV)/BiPhasic mode.
Describes Continuous Positive Airway Pressure with Pressure Support Ventilation.
Explains the functionality and settings for apnea backup ventilation.
Describes Nasal CPAP and Nasal Intermittent Mandatory Ventilation.
Explains how to initiate and use the Standby mode for the ventilator.
Sets the volume limit for pressure-limited breaths to terminate inspiration.
Sets the minimum tidal volume delivered in pressure control breaths.
Controls the slope of the pressure rise during a mandatory breath.
Sets the percentage of peak flow to terminate inspiration in pressure/TCPL breaths.
Allows selection between Square or Decelerating waveforms for volume breaths.
Enables sigh volume breaths every 100th breath in certain modes.
Sets the background flow for breath triggering and flow triggering.
Sets the pressure level below PEEP to trigger inspiration.
Describes Vsync, a feature for synchronizing breaths and pressure control.
Controls the slope of pressure rise during PRVC/Vsync breaths.
Controls the slope of pressure rise during pressure-supported breaths.
Sets the percentage of peak flow to terminate a PSV breath.
Controls the maximum inspiratory time for pressure-supported breaths.
Sets the volume limit for pressure-limited breaths.
Sets the length of the Time High trigger (Sync) window.
Sets the length of the Time Low trigger (Sync) window.