AD 75LGR Technical Data
ghi_td000349gb.fm 25
5 Technical Data
5.1 Machine
Model AD 75LGR
Machine
Weight kg (lb) 45.4 (100)
User interface type Electronic controls,
push button operation
Power supply cord length m (ft) 7.6 (25)
Drainage hose length m (ft) 9.1 (30)
Air filter type Standard
Optional
MERV 7—Pleated paper
MERV 1—Washable cartridge
Discharge air duct size in. 5 (x 2)
Capacity
(AHAM 80°F (27°C), 60% RH)
L/day
(ppd)
35.5
(75)
Capacity at saturation L/day
(ppd)
71
(150)
Air flow volume m
3
/hr
(cfm)
510
300
Machine temperature range °C (°F) 0.5–40 (33–104)
System type Low Grain Refrigerant (LGR)
Compressor type Rotary
AC power requirements V/Hz 115 / 60
Amp draw A 8.7
Circuit rating A 15
Number of blower speeds 1
Drainage pump purge types Automatic and manual
Defrost type Temperature-sensed (thermistor)
Hour meter type Digital display with battery backup
Standards cCSAus