7-18 BA E16 en* 1.0 * E16_10_700.fm
7 Maintenance
Hydraulic oil types
Replacement intervals
Replace the hydraulic oil and hydraulic oil filter depending on the
percentage of hammer operation.
Viscosity class Ambient temperature
min. °C min. °F max. °C max. °F
ISO VG32 -20 -4 30 86
ISO VG46 -5 23 40 104
ISO VG68 5 41 50 122
Percentage of hammer
work
Hydraulic oil Hydraulic oil filter
20% 800 o/h
300 o/h
40% 400 o/h
60% 300 o/h
100 o/h
Over 80% 200 o/h