BA E16 en* 1.0 * E16_10_700.fm 7-37
Maintenance 7
NOTICE
Possible engine damage due to low coolant level.
Check the coolant level once a day.
Information
Check the coolant level once a day before starting the engine.
Observe the coolant compound table
Check and top off the coolant
1. Preparations see chapter “ Parking the machine” on page 5-12
2. Carefully unscrew the filler cap A and release the pressure.
3. Check the coolant in the radiator B.
4. Top off the coolant until the coolant reaches the filler inlet of the
radiator B.
5. Tighten filler cap A.
6. Check the coolant level in the expansion tank C.
7. Top off the coolant until the coolant reaches the mark FULL in the
expansion tank C.
8. Start the engine and let it warm up for about 5 – 10 minutes.
9. Stop the engine.
10.Remove the starting key and carry it with you.
11.Let the engine cool down.
12.Check the coolant level again.
13.If necessary, add coolant and repeat the procedure until the coolant
level remains constant.
14.Close and lock the engine cover.
Information
Check the coolant level once a day before starting the engine.
Observe the coolant compound table.
Fig. 286
C
A
B
LOW
FULL
FULL
C
B