EasyManuals Logo

Wacker Neuson PT 3 User Manual

Wacker Neuson PT 3
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #29 background imageLoading...
Page #29 background image
PT 3 / PT 3A / PT 3H Operation
wc_tx001779gb.fm 29
4.10 Cold Weather Starting (Hatz)
See Graphic: wc_gr000016
4.10.1 Set speed control lever (a) either to 1/2 START or max. START
position, as desired or necessary.
4.10.2 Remove the top of the air cleaner and the soundproofing enclosure (c).
4.10.3 Pull the oil feed knob up to its limit (d) and then push it back down to
its seat.
Note: This ensures that the correct amount of oil will be fed to the
engine when starting. The oil feed device automatically refills when
the engine is running.
NOTICE: The oil feed device should only be used once per starting
attempt.
4.10.4 Re-attach parts previously removed to the engine, then start it
immediately.
4.11 To Stop (Hatz)
See Graphic: wc_gr000016
4.11.1 Move engine speed control lever (a) to the STOP position.
4.11.2 Press in the STOP pin (e) for as long as it takes to stop the engine.
4.12 Operation
Pump should begin pumping water within a minute depending on
length of suction hose and height of pump above water. Longer hoses
will require more time.
If pump does not prime, check for loose fittings or air leak in suction
hose. Make sure strainer in water is not blocked.
Run engine at full speed while operating pump.
4.12.1 Do not pump corrosive chemicals or water containing toxic
substances. These fluids could create serious health and
environmental hazards. Contact local authorities for assistance.
WARNING