Operator’s Manual
Pump
PT 2
PT 2A
PT 2H
5000185192 10 0711
5000185192
EN

Questions and Answers

  • J
    jamiejohnsonAug 8, 2025
    What to do if my Wacker Neuson PT 2 Power Pump won't take in water?
    • S
      Stacy ConwayAug 8, 2025
      If your Wacker Neuson Power Pump isn't taking in water, several factors could be the cause. First, ensure there's enough priming water in the housing. Check that the engine speed is properly adjusted and not too low. Inspect the strainer for any blockages and clean it if necessary. Examine the suction hose for damage and repair or replace it if needed. Also, verify there are no air leaks at the suction port by ensuring the fittings are tight and the housing cover O-rings are sealing correctly. Confirm that the pump isn't positioned too high above the water source. Clear any debris that may have accumulated in the pump housing. Finally, check the clearance between the impeller and insert.
  • G
    georgethomasAug 13, 2025
    Why is my Wacker Neuson PT 2 taking in water but has little or no discharge?
    • M
      Mr. Craig BonillaAug 13, 2025
      If your Wacker Neuson Power Pump is taking in water but has little to no discharge, the issue could stem from a few reasons. Make sure the engine speed is adequately adjusted. Check the suction strainer for partial blockages and clean it thoroughly. Inspect the impeller for wear; you may need to adjust the clearance by adding shims or consider replacing the impeller altogether. Lastly, examine the volute insert for wear or damage, adjusting the clearance or replacing the insert as necessary.
  • T
    Terry BlackAug 20, 2025
    How to fix a Wacker Neuson PT 2 with an impeller that won't turn and is hard to start?
    • J
      Jacqueline RiveraAug 20, 2025
      If the impeller of your Wacker Neuson Power Pump won't turn and the pump is hard to start, it might be jammed or blocked. Begin by opening the pump cover and cleaning any dirt and debris from inside the pump housing. Also, the impeller and insert might be binding; try adjusting the clearance by removing a shim from behind the insert.
  • B
    Bryan KirkAug 27, 2025
    What causes a suction hose leak at the inlet of a Wacker Neuson PT 2 Power Pump?
    • B
      Benjamin WoodAug 27, 2025
      A suction hose leak at the inlet of your Wacker Neuson Power Pump could be due to several reasons. The clamps may not be sealing properly; try tightening them, replacing them, or adding an additional clamp. The hose diameter might be too large for the inlet. The hose could also be damaged and need replacing.
  • L
    Lauren MitchellSep 1, 2025
    What to do if the discharge hose keeps coming off the coupling on my Wacker Neuson PT 2?
    • M
      melissa28Sep 1, 2025
      If the discharge hose of your Wacker Neuson Power Pump keeps detaching from the coupling, the pressure might be too high for the clamps you're using; consider adding another clamp. Additionally, inspect the hose for kinks or blockages that may be causing the issue.

Wacker Neuson PT 2 Specifications