PT 3 / PT 3A / PT 3H Maintenance
wc_tx001776gb.fm 47
5.15 Storage
If pump is being stored for more than 30 days:
Do not open priming plug, discharge plug, or cover when pump is hot.
5.15.1 After pump has cooled, remove discharge plug from pump housing
and drain out any water left in the housing.
5.15.2 Remove pump cover and clean inside of pump housing. Coat inside of
pump with a light film of oil to reduce corrosion. A spray can of oil works
well for this.
5.15.3 Tape up suction and discharge ports to prevent anything from falling
into pump.
5.15.4 Change engine oil and follow procedures described in engine manual
for engine storage.
5.15.5 Cover pump and engine and store in a clean, dry area.
5.16 Accessories
Wacker Neuson offers a complete line of fittings, hoses, and clamps to
properly connect the pump to match various job conditions.