Technical Data PT 2 / PT 2A / PT 2H
50 wc_td000460gb.fm
6.2 Pump
6.3 Sound Measurements
The required sound specification, Paragraph 1.7.4.f of 89/392/EEC
Machinery Directive, is:
Guaranteed sound power level (L
WA
) = PT 2A 102 dB(A), PT 2H 107
dB(A), PT 2 101 dB(A).
The sound pressure level at operator’s location (L
pA
) = PT 2A 91
dB(A), PT 2H 99 dB(A), PT 2 89 dB(A).
These sound values were determined according to ISO 3744 for the
sound power level (L
WA
) and ISO 6081 for the sound pressure level
(L
pA
) at the operator’s location.
Item No.
PT 2(I) PT 2 PT 2A PT 2H
Pump
Dimensions mm (in.) 550 x 465 x 500
(21.7 x 18.3 x 19.6)
590 x 495 x 510
(23.2 x 19.4 x 20)
Weight kg (lb) 43 (96) 59 (131)
*Max. Suction Lift m (ft) *7.5 (25)
Max. Total Head m (ft) 32 (106)
Max. Pressure bar (psi) 3,2 (46)
Max. Flow Rate m³/hr
(gpm)
48
(210)
Suction / Discharge Dia. mm (in.) 50 (2)
Max. Solid Size mm (in.) 25 (1)
*Based on pump operating at sea level. Maximum suction lift will be less at higher altitudes.