EasyManua.ls Logo

WAGNER W 640 - Measuring Viscosity and Technical Data; Viscosity Measurement Procedure; Viscosity Table Reference; Component Identification

WAGNER W 640
38 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GB
3
Measuring the Viscosity
1. Stir the coating material thoroughly before measuring.
2. Dip the viscosity test cup (Fig. 2. a or b) completely into the coating material.
3. Hold the test cup up and measure the time in seconds until the liquid empties out.
(Fig. 2)
This time is called "Runout Time in Seconds".
W 640
Viscosity Table
Spray material Runout Time in Seconds
Thinner-soluble primers 25-35 30-40
Thinner-soluble varnishes 15-35 20-45
Water-soluble primers 25-35 30-40
Water-soluble varnishes 20-30 20-35
Wood preservatives, strippers, oils undiluted
Disinfectants, plant protectants undiluted
Automobile spray paint 20-30 20-35
Description (Fig.1)
1 Air cap 8 Air hose
2 Nozzle 9 Carrying belt
3 Union nut 10 Air filter
4 Spray gun 11 Mains lead
5 Trigger guard 12 Spray gun holder
6 Material volume adjustment 13 Container
7 ON / OFF switch
Technical Data
Max. Viscosity: 35 DIN-s
Voltage: 230 V - 240 V~
Power consumption: 300 W
Atomisation power: 80 W
Double insulation:
Sound pressure level: 80 dB (A)
Oscillation level: < 2,5 m/s²
Air hose length: 1,8 m
Weight: 2,1 kg

Related product manuals