Measuring the Viscosity
1. Stir the coating material thoroughly before measuring.
2. Dip the viscosity test cup (Fig. 2. a or b) completely into the coating material.
3. Hold the test cup up and measure the time in seconds until the liquid empties out.
(Fig. 2)
This time is called "Runout Time in Seconds".
W 650
Viscosity Table
Spray material Runout Time in Seconds
Large Small
Test Cup Test Cup
Thinner-soluble primers 25-40 30-45
Thinner-soluble varnishes 15-40 20-50
Water-soluble primers 25-40 30-45
Water-soluble varnishes 20-35 20-40
Wood preservatives, strippers, oils undiluted
Disinfectants, plant protectants undiluted
Automobile spray paint 20-35 20-40
Description (Fig.1)
1 Air cap 8 Air hose
2 Nozzle 9 Carrying belt
3 Union nut 10 Air filter
4 Spray gun 11 Air screen
5 Trigger guard 12 Mains lead
6 Material volume adjustment 13 Spray gun holder
7 ON / OFF switch 14 Container
Technical Data
Max. Viscosity: 40 DIN-s
Voltage: 230 - 240 V ~
Power consumption: 350 W
Atomisation power: 95 W
Double insulation:
Sound pressure level: 80 dB (A)
Oscillation level: < 2,5 m/s²
Air hose length: 1,8 m