23
TROUBLESHOOTING
PROBLEM
Buoyancy chamber loses
air:
Boat does not get on
plane:
Boat porpoises:
Boat rides bow down:
Water accumulates in
hull:
POSSIBLE CAUSE
- Tube valve is loose.
- There is a leak.
- Motor is improperly trimmed.
- There is too much load.
- Motor is too small.
- Motor is improperly trimmed.
- Boat is loaded incorrectly.
- Motor is improperly trimmed.
- Boat is loaded incorrectly.
- Drain plug is open.
POSSIBLE SOLUTION
- Tighten valve (see OPERATION OF VALVES).
- Repair leak (see REPAIRS).
- Adjust motor trim (see MOTOR TRIM).
- Adjust load (see LOADING).
- Change motor size (see MOTOR SELECTION).
- Adjust motor trim (see MOTOR TRIM).
- Adjust load (see LOADING).
- Adjust motor trim (see MOTOR TRIM).
- Adjust load (see LOADING).
- Close drain plug (see FEATURES & DECK PLANS).