8
- Ensure lter bowl (H) is tightened. (Hand tighten only). Install the hose
- Ensure drain valve (K) is closed.
Place unit indoor, on a smooth level surface away from exposure to direct
sunlight. Use only genuine Bio-Circle Lcleaning solution
(55-A 007, 20 liters / 5.3 gal. or 55-A 008, 208 liters / 55 gal.).
When lling the unit from a drum, ensure the transfer pump being used is clean
and close the drum once done.
Fill the tank to normal operating capacity of up to 80 liters/21.2 gal. Refer to level
lines shown on page 9.
Note: Open the containers vent holes and pour slowly to prevent splashing
and excessive foaming of Bio-Circle L liquid.
3. Plug power cord into properly grounded 3-prong, 120V, 60Hz, outlet protected
by a class A GFCI.
4. Turn main power switch (E) to “I”.
Note: Do not turn ON the main power switch (E) and the cleaning pump switch
(F) with no liquid inside the machine.
5. Allow the heater coil to warm Bio-Circle L™ solution to working temperature
for optimal cleaning efciency. This may take up to 4 hours.
Once the solution has reached its proper working temperature of 41ºC/106°F
(This can take up to 3.5 hours), periodically, the heater will turn itself ON
automatically to maintain the proper working temperature.
Never turn OFF the BIO-CIRCLE™ unit except for servicing.
OPERATING INSTRUCTIONS
The BIO-CIRCLE™ Parts Cleaning System is designed for the removal and
bioremediation of biodegradable oil and grease from ferrous and non-ferrous
parts and other washable surfaces. It is NOT recommended for cleaning other
non-biodegradable substances.
DO NOT INTRODUCE DISINFECTANTS, SOLVENTS, BRAKE FLUID, ENGINE
COOLANT, CHLORINATED, ACIDIC OR ALKALINE SOLUTIONS OR ANY
CLEANING SOLUTION OTHER THAN Bio-Circle LINTO THIS SYSTEM.
DO NOT ADD WATER.
1. Place parts to be cleaned into sink (G). Maximum load capacity is 90 kg/200 lbs.
Do not plug drain to ll cleaning sink. Use optional Parts Washing Basket
(55-B 004) to contain small parts.
Note: Any parts susceptible to oxidation should not be left in the sink (G) after
cleaning.

Table of Contents