EasyManua.ls Logo

W&H implantmed SI-915 User Manual

W&H implantmed SI-915
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Instructions for Use
SI-915 / SI-923
Question and Answer IconNeed help?

Do you have a question about the W&H implantmed SI-915 and is the answer not in the manual?

W&H implantmed SI-915 Specifications

General IconGeneral
ManufacturerW&H
Modelimplantmed SI-915
Maximum power consumption180 W
Data loggingYes
ControlFoot control
ApplicationImplantology
Power Supply100-240V AC, 50/60Hz

Summary

1. Introduction

Introduction and User Safety

Covers device usage, safety warnings, intended purpose, and user qualifications.

Manufacturer's Responsibility

Outlines manufacturer's liability for safety, reliability, and performance based on adherence to instructions.

4. Safety notes

General Safety Precautions

General safety advice including storage, checking for damage, and avoiding hazardous environments.

Operational Safety Warnings

Specific warnings on fuse use, patient contact, using specific handpieces, and behavior during power/system failures.

Power and Cable Safety

Guidance on using the supplied mains cable, earthing, accessibility, and safe disconnection.

Electromagnetic Compatibility Safety

Warns about electromagnetic fields affecting active implantable medical devices (AIMD) and advises patient checks.

Hygiene and Coolant Safety

Instructions on coolant, irrigation tubing, and initial cleaning/disinfection procedures.

5. Description

6. Start-up

Initial Setup and Connections

Step-by-step guide for connecting mains, foot control, motor, irrigant support, and irrigation tubing.

8. Control unit operation

Program Selection and Display

How to activate programs (P1-P5) and interpret display settings for speed and torque.

Speed Adjustment

Procedure for increasing or decreasing motor speed using the PLUS/MINUS buttons within programs P1-P3.

9. Operation

10. Restoring factory settings

11. Thread cutter function (chip breaker mode)

12. Error messages

Troubleshooting Error Codes

Table of error codes (00-99) with descriptions and recommended solutions for the control unit.

13. Hygiene and maintenance

General Hygiene & Maintenance Guidelines

General guidelines for hygiene, maintenance, protective clothing, and approved cleaning agents/disinfectants.

Sterilization Methods & Cycles

Recommends sterilization according to EN 13060, EN 285, or ANSI/AAMI ST55, with specific cycle details.

14. Servicing

17. Data on electromagnetic compatibility according to IEC/EN 60601-1-2

Related product manuals