Ion Pro
®
and CareClear Pro
®
Series
Water Filters
For Models:
• IPHS
• IPFE
• IPG
• IPCG-AN
• CCP
• CCP-AN

Questions and Answers

  • J
    Jared WilliamsSep 23, 2025
    What does error Err 404 mean on Water Care Water Filtration Systems?
    • J
      jennifersolisSep 23, 2025
      If you're seeing error Err – 404, it means corrupt diagnostic display information is stored in the memory. Replace the PC board.
  • U
    ugreenAug 25, 2025
    How to fix no display on Water Care Ion Pro PC board?
    • K
      Kelly CastroAug 25, 2025
      If there's no display on the PC board, begin by checking the power at the electrical outlet; repair or use a working outlet. Ensure the control valve power adapter is correctly plugged into the outlet and connected to the PC board. Verify the power supply to ensure it delivers the correct voltage to the PC board. If these steps don't resolve the issue, the power adapter, PC board, or battery (if present) may be defective and require replacement.
  • M
    Meghan BoyleAug 25, 2025
    What to do if Water Care Ion Pro Water Filtration Systems control valve doesn't regenerate automatically?
    • S
      Stephanie PerkinsAug 26, 2025
      If your control valve only regenerates when you press and hold the correct buttons, but not automatically, there are several possible causes. First, check if the bypass valve is in the bypass position and, if so, turn the handles to the service position. Next, ensure the meter is connected to the meter connection on the PC board. A restricted or stalled meter turbine could also be the problem, so remove the meter and check for rotation or foreign material. Also, verify the meter cable wires are securely installed into the three-pin connector labeled METER. Incorrect programming, a defective meter, or a defective PC board could also be the cause.
  • D
    Daniel CooperAug 27, 2025
    Why does my Water Care Water Filtration Systems control valve regenerate at the wrong time?
    • S
      Susan MooreAug 27, 2025
      If your control valve is regenerating at the wrong time, it could be due to a few reasons. A power outage might have occurred, requiring you to reset the time of day. If your PC board has a battery backup, it may be depleted. Also, the time of day or regeneration time might not be set correctly, so double-check those settings. Lastly, the control valve may be set at 'on 0' (immediate regeneration) or 'NORMAL + on 0' (delayed and/or immediate); in this case, you should check the programming and reset it to NORMAL for a delayed regeneration time.
  • K
    Kristina BradyAug 27, 2025
    Why is there excessive water in the regenerant tank of my Water Care Water Filtration System?
    • R
      Rhonda ChanAug 27, 2025
      Excessive water in the regenerant tank can stem from several issues. Start by checking the refill setting, as improper program settings can cause this. A plugged injector could also be the culprit; remove and clean or replace it. Ensure the drive cap assembly is properly tightened. Damaged seal/stack assembly can also lead to this problem, so replace them if necessary. Check the drain line for restrictions or kinks and clear them. Lastly, inspect the backwash flow controller for blockage and clean or replace it, or verify that the refill flow controller is present and replace if missing.
  • C
    Christopher MarshallSep 18, 2025
    What does error Err 201 mean on Water Care Water Filtration Systems?
    • P
      Pamela KentSep 18, 2025
      If you're seeing error Err – 201, it means that an invalid regeneration cycle step was detected. Replace the PC board.
  • K
    Kari FosterSep 15, 2025
    What does error Err 204 mean on Water Care Ion Pro?
    • B
      Brenda JenningsSep 15, 2025
      If you're seeing error Err – 204, it means a leak has been detected. This occurs when the dP input is active for 'ALARM' and the input is closed. Check for a low flow leak. To clear the error, press the NEXT and REGEN buttons for 3 seconds to resynchronize the software with the piston position, or disconnect the power supply from the PC Board for 5 seconds and then reconnect.
  • V
    Valerie ValenzuelaSep 16, 2025
    What does error Err 109 mean on Water Care Ion Pro Water Filtration Systems?
    • D
      Donna ReedSep 16, 2025
      If you're seeing error Err – 109, it means that an invalid motor state was detected. Replace the PC board.
  • B
    Brian JosephSep 5, 2025
    Why is residual regenerant being delivered to service in my Water Care Water Filtration System?
    • N
      Nicholas WoodSep 5, 2025
      If residual regenerant is being delivered, it could be due to low water pressure; ensure it remains at a minimum of 25 psi. The injector size might also be incorrect for the application, so replace it with the correct size. Additionally, a restricted drain line could be the cause; check for restrictions or debris and clean it.
  • B
    Brent HendersonSep 2, 2025
    What to do if Water Care Water Filtration Systems control valve fails to draw in regenerant?
    • J
      James ThomasSep 3, 2025
      If the control valve isn't drawing in regenerant, start by checking if the injector is plugged; remove and clean or replace it. A faulty regenerant piston could also be the cause, requiring replacement. Inspect the regenerant line for air leaks. Also, check the drain line for restrictions or debris that could cause excess back pressure and clean it. Ensure the drain line isn't too long or high, and shorten it if necessary. Finally, check the incoming water pressure, which must remain at a minimum of 25 psi.