13
1.0 Install the REGP1414E device
1.1 Turn off the water supply to the cold water supply adapter.
1.2 Using a sharp knife or tube cutter, cut the ¼” tube between the Leak Stop device and
the cold water inlet to the RO system. Make sure the cut is straight and without burrs.
1.3 Insert the tube from the cold water supply adapter into the inlet of the REGP1414E
device. Check the arrow on the device to make sure the flow direction is correct. See
figure 2. Make sure the tube is pushed all the way into the fitting and bottoms out. Tug
on the connection to make sure that it is secure.
1.4 Connect the outlet of the device to the tube leading to the RO. Make sure the tube is
pushed all the way into the fitting and bottoms out. Tug on the connection to make sure
that it is secure.
1.5 Turn on cold water supply and check for leaks. Reinstall tube connections if necessary.
Installation is now complete.