WARNING
Lubricants
Do NOT use Vaseline, oils, hydrocarbon lubricants or spray silicone anywhere! Petroleum base lubricants will cause
swelling of o-rings and seals. The use of other lubricants may attack plastic Noryl®. It is recommended that Dow
Corning® silicone grease be used as a lubricant for all control valves. Dow Corning® 7 Release Compound is used in the
manufacture of Chandler Systems control valves. (Part # LT-150)
Sealants
Pipe dope and liquid thread sealers may contain a carrier that attacks some plastic materials. It is recommended that
Teflon® tape be used to seal plastic Noryl® threaded fittings.
General
Specifications
CF10
CF10-3
CF13
CF13-3
Filter Media Smart-Blend Smart-Blend
Filter Media Capacity (cu. ft.) 1.5 2.5
Mineral Tank (Vortech) 10 x 54 13 x 54
Service Flow Rate - Continuous (gpm) 5 8
Service Flow Rate - Intermittent (gpm) 7 10
Backwash Flow Rate (gpm) 5 7
Gallons Used / Backwash 130 182
Space Required (D x W x H) in inches 10 x 10 x 62 13 x 13 x 62
Approximate Shipping Weight 142 lbs. 218 lbs.
Specifications