Procedure for Extended Non-Use
(More than 2 months)
Step A - Turn off the water supply to your RO system at the Adapt-
A-Valve and open the RO faucet to drain the storage tank.
Once the storage tank is empty, remove all filter cartridges
(order not important), place them into a sealed plastic bag
and store in your refrigerator.
NOTICE
DO NOT FREEZE
Restart Instructions
Step A - Reinstall all filters on to the RO unit. Filters are color coded
to match the filter heads they snap in to. Refer to page 7,
Step 11 for cartridge installation procedure.
Step B - Turn on water supply to the system at the Adapt-a-Valve.
Check frequently over the next 24 hours to ensure no
leaks are present.
NOTICE
If you have connected your RO system to a refrigerator / ice
maker, make sure the ice maker is off (do not allow water to flow
to the ice maker) until the tank has been allowed to completely
fill.
Step C - Open the RO faucet and leave it open until water begins to
trickle out (it will come out slowly).
Step D - Close the RO faucet allowing the storage tank to fill with
water. It may take 3 to 6 hours to fill the tank completely
depending on the production capability of the membrane,
local water temperature and water pressure.
Step E - After the Tank has filled, open the RO Faucet to flush the
tank completely. You will know that the tank is empty
when the flow rate from the RO faucet is down to a trickle.
The second tank can be used for drinking.