CHAPTER 10 CLICK 112/114 111
Note
For specific information on how to use the Click 112/114 with the SmartSensor Matrix,
see the SmartSensor Matrix User Guide.
Configuration
e Click 112/114 can be congured in three ways: DIP switches, the front panel menu, and
Click Supervisor.
ese three conguration methods can congure dierent sets of parameters; some of these
parameters can be set using multiple conguration methods, and some of them can only be
set using one particular method. Table 10.2 lists how each parameter may be accessed and
congured.
DIP Switch Front Panel Menu Click Supervisor
Baud Rate Yes Yes Yes
Channel Input Map Yes Yes Yes
Autobaud No Yes No
Reset to Default No Yes Yes
Description No No Yes
Location No No Yes
Device ID No No Yes
To use this
configuration feature:
Hardware mode Software mode Software mode
Table 10.2 – Click 112/114 Configuration Options
e nal row on the table refers to conguration modes. e DIP switches can be used to
choose between Hardware and Soware modes. If any of the switches are set to the ON
position, that particular parameter is set to Hardware mode and only the DIP switches can
be used to change its conguration options. If all switches are set to the OFF position for a
particular parameter, it is in Soware mode and the front panel menu and Click Supervisor
may be used to change conguration options. is will be discussed in greater detail in the
DIP Switches section of this chapter.
Note
Any setting which has been configured via the DIP switches will be read-only in Click
Supervisor and the front panel menu.