The WTC-3 will stop the system pump when there are no
r
equests from room thermostats. In this case, all actuators
a
re closed down and the pump will stop.
Output eight on the unit switches on if the output of at
l
east one control circuit switches on. The output may be
u
sed for the activation of the pump.
N
N
o
o
t
t
e
e
:
If analogue thermostats are connected to the base unit
then the out of use thermostat inputs must be connected
in parallel with the heating/cooling changeover input,
otherwise output eight will remain continuously switched
on in the cooling mode. This will keep the pump activated
during the cooling period.
N
N
o
o
t
t
e
e
:
this output is supply 230V