NiteCool TCC-100/RCC-100 parking cooler system
12
10. The blower must be switched on at
least once every month, even in winter
time, for 10 minutes to preserve the easy
movement of all movable parts.
11. Failure to follow the installation and
service manual and the notes contained
therein will lead to all liability being refused
by Webasto. The same applies if repairs
are carried out incorrectly or with the use
of parts other than genuine spare parts.
2 General
For rapid cooling of the interior of the
vehicle when the outside temperature is
high and the sun is shining into the cab, we
recommend initially running the blower at
maximum with the cooling function
switched on. Once a pleasant interior
temperature has been achieved, you can
reduce the blower to a lower setting
according to your requirements.
If the sunshine has heated up the vehicle
considerably, we recommend opening the
doors and windows with the vehicle at a
standstill to allow ventilation to take place
before switching on the parking cooler
system.
Before starting a drive and when you have
finished your working day, check the
content of the water tank and refill if
necessary.
To avoid damage due to the water freezing
in cold weather, drain all of the water from
the parking cooler system.
If it is necessary to tilt the cab, first wait
three to four minutes after switching off the
parking cooler system to allow all the
water contained in the piping system to
drain back into the water tank.
Evaporator unit
The following guidelines must be followed:
The parking cooler system is equipped
with an evaporator unit for cooling the air.
This must be renewed every six months or
according to the level of contamination.
We recommend fitting a new evaporator
unit before the start of the hot weather
season.
Evaporator units are available from your
Webasto Installation and Service station.
WARNING!
Batteries from our products are to be
returned to the point of sales or nearby
when used.
Returning is free of charge.
The consumer is legally obliged to return
used batteries.
Batteries are by no means to be disposed
of with domestic refuse.
Risk of explosion if the batteries are
exchanged improperly!
Follow the instructions to dispose of the
batteries!
This product is subject to the EC directives
2002/96EC and EN 50419. Notes on
disposal are supplied with the sample or
the operating instructions.
WARNING!
The water tank must always be filled with
drinking water. Do not add any perfumes
or other products to the water that have
not been approved by Webasto.
The water piping system must be cleaned
as follows, at least every two months:
a) - First drain the entire system by
removing the tank drain cover from the
water tank.
b) - Then screw the tank drain cover back
on and fill the water tank half full with a
solution of drinking water and a