Symptom Possible cause Remedy
No cooling power Water pumps not running Check the connection to the water pumps
Check fuses
Water level sensors are providing incorrect
information
Check water level sensors
Clean water tank
Water pipes kinked or squashed
Remedy the cause of the fault, seal any leaks
Water pump pressure too low Check water pump function
Filter insert in water tank or precooling chamber
clogged
Clean
Reduced cooling
power
Evaporator unit contaminated Renew evaporator unit
Water flow rate too low Water line routed so it is kinked or squashed. Re-lay
hoses. Water pump pressure too low (see above for
remedy)
Water leaks from
parking cooler
system
Hose connection loose Check the hose lines are connected firmly
Water hose damaged Route a new hose and connect it
No ventilation Blower does not function Check the fuses and plug connectors
Check the blower motor function
Check the battery voltage