EasyManua.ls Logo

Webasto SmarTemp Control fx 2.0 - Definitions

Webasto SmarTemp Control fx 2.0
8 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SmarTemp Control fx 2.0 Installation Operation Instructions
4
Definitions Default
LVD
LVD “Low Voltage Disconnect” allows the user to adjust the battery voltage level at
which the Webasto SmarTemp Control fx 2.0 will shut the heater off. A warning (LED
and message) will appear after 8 minutes of low voltage. The warning will remain on
for 2 minutes before the heater is shut off.
If battery voltage is equal to or less than the threshold selected +0.1v, the heater will
not start. i.e. if an 11.5v threshold is selected the heater cannot be started until B+ has
reached 11.7v.
12 volt - Range between 11v 12.5v | 24 volt - Range between 21v 25.5v
11.4v |
24.2v
Default
Default allows the user to perform a reset to all default values.
Note: A power loss will not reset user programmed values.
N/A
Password
A password can be set to prevent access to the advanced “Options” menu. Enter a 4
digit code passcode to begin securing the Options menu. Note: This is typically used in
fleet vehicle applications.
OFF
Hour
Meter
The hour meter logs the operating hours of an active ON signal to the heater. This
does not reflect the true runtime of the heater itself.
Note: For warranty purposes a diagnostic printout is still required where applicable.
This hour meter is for reference only!
N/A
SW
Version
This displays the firmware version of the Webasto SmarTemp Control fx 2.0. Installed
Version
Back
Select this to return to the previous screen.
N/A
IMPORTANT - The Red status indicators (heater "ON") and LCD screen backlight turn off after 30 seconds. A
touch of any button or a turn of the rotary knob will re-activate these lights. If the "Webasto" button is used to re-
activate these lights, an additional press of this button is necessary to turn the heater off. Note that when the
heater is "ON" the display is active.