Summary

Safety

General Safety Considerations

Discusses general safety points for using the monitor.

Electrostatic Discharge (ESD) Precautions

Explains ESD and precautions for handling sensitive components.

Service Overview

Functional Verification

Functional Verification Overview

Introduces the functional test procedure for preventive maintenance.

Equipment Required

Lists the necessary equipment for performing functional verification.

Functional Verification Procedure

Details the step-by-step procedure for functional verification.

NIBP Testing

Covers NIBP characterization, leak tests, and pressure calibration verification.

NIBP Leak Test

Tests the NIBP system for abnormal leakage.

NIBP Pressure Calibration Verification

Verifies pressure readings against a calibrated external pressure meter.

NIBP Overpressure Tests

Tests the monitor's overpressure cutoff feature for safety.

Printer Functional Test

Procedure to test the monitor's printer functionality.

SpO2 Testing

Covers testing the monitor's SpO2 function with Nellcor and Masimo sensors.

Nellcor SpO2 Testing

Tests the monitor's SpO2 function using a Nellcor functional tester.

Masimo SpO2 Testing

Tests the monitor's SpO2 function using a Masimo functional tester.

SpO2 Sensor Testing

Tests the SpO2 function and verifies sensor performance with a simulator.

Temperature Verification

Covers tests for the monitor and probe temperature functions.

Monitor Temperature Test

Tests the monitor's temperature measurement function using a test key.

Patient Isolation Test

Explains the patient isolation test overview and its importance.

Patient Isolation Test Procedure

Provides the procedure for conducting the patient isolation test.

Troubleshooting and Repair

Troubleshooting Chart

Provides a chart linking symptoms to possible causes and suggested repair actions.

NIBP Characterization

Explains the process of characterizing the NIBP module for accurate operation.

Welch Allyn Monitor Service Utility

NIBP Characterization Procedure

Details the procedure for training the NIBP module.

NIBP Characterization with Utility

Step-by-step guide to characterize the NIBP module using the utility.

Disassembly Procedure

Replacement Parts