TROUBLESHOOTING
IMPORTANT: If trouble persists please call our customer help line at (888) 315-3080
M-F 8-5.
Problem
Engine will not
start
Engine runs but
there is no
electrical output
Generator runs bul
does not support
all electrical
devices
connected.
Cause
Engine switch is set
LO"Off".
Fuel valve is turned
Lo"closed".
Shoke is open.
Engine is out of gas.
Engine is filled with
sontaminated or old
gas
Spark plug is dirty.
Spark plug is
3roken.
Generator is not on
evel surface.
:Dilis low
Sircuit breaker is off.
Bad connecting
Mres/cables.
Bad electrical device
sonnected to
generator.
Generator is
3verloaded
Short in one of the
sonnected devices.
_,ircleaner is dirty.
Solution
Set engine switch to "on".
Turn fuel valve to "open" position.
Close the choke
&dd gas.
Change the gas in the engine.
Clean spark plug.
Replace spark plug.
Move generator to a level surface to prevent low oil shutdown
from triggering.
Add or replace oil.
Set the circuit breaker to the "on" position.
If you are using an extension cord, try a different one.
Try connecting a different device.
Try connecting fewer electrical loads to the generator.
Fry disconnecting any faulty or short-circuited electrical loads.
Clean or replace air cleaner.
25