2 Where
engines are
freshwater cooled, anti-freeze
should
be added
to
closed circuit
system
to manufacturer's
recommendation.
3
Disconnect
exhaust
tubing
from
engine;
using
plastic
tape,
tape over
exhaust outlet
on engine.
Pinch
up
jubilee
clip
onto exhaust
tube
so
that it
can be
found easily
when
commissioning.
4 Flemove
air cleaner,
tape up air
inlet
on engine
and
inlet
and outlet
ports
on air
cleaner
itself,
store
air cleaner
in
galley
locker.
5
Remove impeller(s) from coolant water circulating
pump
and
secure
to
pump
for
easy
location when commissioning.
7
Completely
fill fueltank.
Electrics
and
General
1 Disconnect
ship's batteries and
pull
battery
cables well
clear of
terminals.
2
Spray exposed electrics and
wiring
terminations with
WD40,
and
pay particular
attention to
battery
master
switch.
3 Ensure
batteries are moved from items
of equipment such
as echo-sounders, radios,
logs,
etc.
4
Gompletely
dry out
toilet installation
after
testing.
5
Ensure
domestic fresh water
system
is
drained as
far
as
possible.