Lit. No. 49513, Rev. 04 60 June 15, 2022
OPERATING YOUR SNOWPLOW
HYDRAULIC SYSTEM
The FloStat
®
hydraulic unit's valve manifold
includes relief valves to prevent damage to the
blade or vehicle if an obstacle is hit at either end
of the blade. The valves are preset at the factory
and do not need any adjustments unless the valve
manifold is serviced. When force against the
blade causes the pressure in an extended ram to
exceed set limits, the relief valve opens, allowing
uid to escape and the ram retracts.
For hydraulic uid type and lling instructions, see
"Annual Fluid Change" under "Hydraulic System"
in the Maintenance section of this manual.
MVP PLUS™ Blades
Quill
Breather
Fill
Plug
Drain Cap Motor
Motor
Relay
Valve
Manifold
Reservoir
HTS™ Blades
Quill
Breather/
Fill Plug
Drain
Plug
Motor
Valve
Manifold
Reservoir
Straight Blades
Quill
Breather
Fill
Plug
Drain Plug
Motor
Valve
Manifold
Reservoir
WIDE-OUT™ Blades
Quill
Breather
Fill
Plug
Drain Cap
Motor
Motor
Relay
Valve
Manifold
Reservoir

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Western UltraMount and is the answer not in the manual?

Western UltraMount Specifications

General IconGeneral
BrandWestern
ModelUltraMount
CategorySnow Blower
LanguageEnglish

Related product manuals