How to start a Westinghouse Inverter generator that won't start?
- BBilly HartNov 2, 2025
If your Westinghouse Inverter generator won't start, there are several things you can check: * Ensure the oil level is adequate and add oil if needed. * Make sure the generator has enough fuel. * Verify the fuel isn't stale or contaminated; if it is, drain and refill with fresh fuel. * Unplug any electrical cords or devices from the 240-Volt AC receptacles. * Confirm the fuel cap vent and fuel control switch are in the ON position. * Adjust the choke knob to the START position if the engine is cold, or adjust accordingly if the engine is hot. * Check that the spark plug boot is properly connected and the spark plug is clean and not faulty. * Inspect the air filter and spark arrestor for dirt or blockages. If none of these steps work, the generator may be faulty, and you...