Westinghouse iGen Series - User Manual

Westinghouse iGen Series
85 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
iGen2300
Digital Inverter Generator
1800 Running Watts | 2300 Peak Watts
iGen2600
Digital Inverter Generator
2200 Running Watts | 2600 Peak Watts
FOR MODELS:
USER MANUAL

Questions and Answers

  • C
    Chloe WhiteJul 28, 2025
    What to do if my Westinghouse Inverter engine will not start?
    • B
      Brittany KrauseJul 28, 2025
      If your Westinghouse Inverter engine won't start, several factors could be at play. First, ensure the inverter has gasoline. If it does, inspect and clean the fuel delivery passages for any obstructions. Also, check and clean the air filter. Verify the oil level and add oil if necessary, as a low oil level shutdown switch might be preventing the unit from starting. Make sure the spark plug boot is fully engaged with the spark plug tip. Remove and check the spark plug, replacing it if faulty. Check and clean the spark arrestor. Finally, drain any stale fuel and replace it with fresh fuel.
  • M
    Megan MorseAug 4, 2025
    Why does my Westinghouse Inverter suddenly stop running?
    • D
      David RiosAug 5, 2025
      Your Westinghouse Inverter might suddenly stop running due to a few reasons. Primarily, check the fuel level and add fuel if necessary. Another cause could be the low oil shut down switch, so check the oil level and add oil if needed. Lastly, too much load can cause the inverter to stop. Try restarting the inverter and reducing the load.
  • J
    James SmithAug 11, 2025
    How to fix a Westinghouse Inverter with no electrical output but running engine?
    • J
      Jamie MorrisAug 12, 2025
      If your Westinghouse Inverter engine is running but there's no electrical output, try these steps: First, check if the reset breaker is tripped and reset it. Next, verify that the power cord’s plug connector is fully engaged in the inverter’s outlet. If that's not the issue, the power cord might be faulty, so replace it. Finally, the electrical appliance itself might be defective; try connecting a known good appliance to verify the inverter is producing electrical power.
  • J
    Jay BryantAug 20, 2025
    Why does the Westinghouse Inverter engine run erratic?
    • H
      hhallAug 20, 2025
      If your Westinghouse Inverter engine runs erratically and doesn't hold a steady RPM, it could be due to a few reasons. First, make sure the choke is not left in the CHOKE position; move it to the RUN position. Also, check and clean the air filter. Keep in mind that if applied loads are cycling on and off, changes in engine speed may occur, which is a normal condition.

Summary

Westinghouse User Manual

Safety

Technical Specifications

Unpacking

Operation

Before Starting the Inverter

Pre-operation checks and location selection guidelines for safe and proper use.

Initial Oil Fill

Starting the Inverter

Stopping the Inverter

Resetting the Reset Breaker

Procedure to reset the inverter's circuit breaker after an overload condition.

Maintenance

Maintenance Schedule

Summary of owner-performed maintenance tasks and their recommended intervals.

Engine Oil Maintenance

Specifications for engine oil and procedures for checking and adding oil.

Air Filter Maintenance

Guidelines for cleaning and maintaining the inverter's air filter.

Troubleshooting

Schematic Diagram

iGen2300 Specifications

iGen2600 Specifications

Westinghouse iGen Series Specifications

General IconGeneral
BrandWestinghouse
ModeliGen Series
CategoryInverter
LanguageEnglish