19. Command Codes EXPLANED
Command 1: Machine Test
There are 3 options.
Test 1 - consists of opening & closing the delivery doors in
sequence followed by rotation of the drums where applicable.
The test will stop as soon as an operating anomaly is detected
and the corresponding error code will appear on the display.
Test 2 - tests opening / closing of the delivery doors manually by
means of selection buttons.
Test 3 - allows testing of distance between zero position sensor
and magnets of all 8 drums.
Command 2: Submenu for setting the clock and daily timers
Key in 02, press ENTER, Alarm 00 will appear on the display,
follow the on screen instructions.
Command 3: Setting the prices
Enter the number of the drum in which you want to change the
price and press ENTER. The price appears on the display. Enter
the new value and press ENTER to save it or ESC to return to
menu without changes.
Programming the value of the full prices changes the value of
the corresponding discounted price and equals them.
Therefore, if you sell at differentiated prices, you must first
program the full price and then the discounted price and never
vice-versa.
C O M M A N D S T O A C C E S S T O S U B - M E N U S