0805_GB_42 - GAS FRYERS 04/2008
5 · 12
2 - CHARACTERISTICS OF THE APPLIANCES
3 - TECHNICAL DATA
These appliances are used for professional purposes. Installation,
repair and use must be carried out by expert personnel.
These instructions for installation are for our gas fryers set up for
the category in the table 1 on pag. 5. The data plate is located on
the appliance, see diagram. Beware of inexpert handling.
Model
ADN 625
ADN 626
Description
Gas fryer - 1 vessel
Gas fryer - 2 vessels
N˚ Tank
1
2
Capacity
10 l
10 l + 10 l
Dimensions in mm. (LxDxH)
400 x 700 x 900
800 x 700 x 900
N.
51BS2548
51BS2548
Primary air distance “A” mm
Methane gas G20
Liquid gas G30/G31
Category
Construction type
Air necessary for combustion
Nominal thermal power
Minimum thermal power
Overall thermal power (gas)
Connection pressure
Methane gas 2H
Liquid gas 3+
Gas connection values
Methane gas 2H
Liquid gas 3+
Nozzles Ø 1/100 mm
Main burner
G20
G30/G31
(HuB = 9.45 kWh/m
3
) in m
3
/h
(HuB = 12.87 kWh/kg) in kg/h
Nominal thermal power
Minimal thermal capacity
Nominal thermal power
Minimal thermal capacity
G20
G30/G31
20 mbar
28/37 mbar
II2H3+
A
m
3
/h
kW
kW
No. of nozzles pilot burner
G20
G30/G31
1
2
0.730
0.540
2 x 145
-
2 x 95
-
Adjustable
20
1
2
1.460
1.080
4 x 145
-
4 x 95
-
Adjustable
2 x 20
Model
ADN 625
14
6.9
-
ADN 626
28
6.9 + 6.9
-
0051
TIPO/TYPE
CAT/KAT GAS/GAZ G30 G31 G20 G25
II2H3B/P P mbar 30 30 20 -
II2H3+ P mbar 30 37 20
-
-
II2H3+ P mbar 28 37 20 -
25II2L3B/P P mbar 30 30
II2ELL3B/P P mbar 50 50 20 20
II2E+3+ P mbar 28 37 20 25
II2H3B/P P mbar 50 50 20 -
I2E P mbar - - 20 -
--II2H3B/P P mbar 30 30
II2H3+ P mbar 28 37 20 -
--
--
I3B/P P mbar 30 30
I3+ P mbar 28 37
SE FI DK CZ SK SI
IT CH PT
ES IE GB GR
NL
DE
FR BE
AT CH
LU
EE LV LT
EE LV LT
NO MT CY IS HU
CY
MOD.
MOD.
ART.
N.
N.
Qn kW
m
3
/h
MADE IN ITALY
Predisposto a gas: - Gas preset: - Prevu pour gaz:
Eingestelt für Gas: - Preparado para gas: -
Geschuckt voor:
V AC kW Hz
THE APPLIANCE MUST BE CONNECTED IN COMPLIANCE WITH THE LAWS IN FORCE
AND INSTALLED IN A WELL-VENTILATED ROOM. READ THE INSTRUCTION MANUALS
BEFORE INSTALLING AND USING THE APPLIANCE.
THE APPLIANCE MUST BE INSTALLED BY QUALIFIED PERSONNEL.
G30/G31 28/37 mbar
G20 20 mbar