SERVICE
Whirlpool Europe DWF 405 S 23.05.2002 / Page 3
Customer Service 8545 405 01770 Doc. No: 4812 718 18048
Technical data
Rotations
Spray pump motor 2800 RPM
Drain pump motor 3000 RPM
Spray arm lower 30 - 40 RPM
Spray arm upper 30 - 40 RPM
Flow rates/ Inlet volume
Flow meter (at 0.3 bar
= quantity 1.1 l/min) 208 lmp/l
Spray pump 45 - 65 l/min
Drain pump 16 l/min
Pump height max. 1.1 m
Inlet valve 4 l/min
Spray arm lower ~ 33 l/min
Sprayarm upper ~ 27 l/min
Ceiling rotor ~ 8 l/min
Electrical base data
Voltage 220/ 230 V
Frequency 50 Hz
Total power 2.0 - 2.2 kW
Fuse 10 A
Motor
Spray pump motor permanent spray system
Voltage 220/ 240 V
Power consumption 145 W
HI 69 Ω
HA 48 Ω
Capacitor 4 µ F
Drain pump motor
Voltage 220/ 240 V
Power consumption 30 W
Resistance 146 Ω
Heating
1 Element system
Voltage 220/ 230 V
Power consumption 1.87/ 2.04 kW
Resistance 24.5 Ω
Heating speed ~ 2.0 ˚C/min
Temperature on surface ~ 115 ˚C
Safety thermostat
self reset
(Temperature of water) ~ 85 ˚C
Fuse 206 ˚C
Double electric inlet valve
Voltage 220/ 240 V
Frequency 50/ 60 Hz
Resistance 2.0 kΩ
Regenerating valve
Voltage 220/ 240 V
Frequency 50/ 60 Hz
Resistance 3.13 kΩ
Coil of dispenser
Voltage 220/ 240 V
Frequency 50/ 60 Hz
Resistance 1.3 kΩ
Reed contacts
flow meter
NTC
20 ˚C 58.1 kΩ
25 ˚C 47.1 kΩ
30 ˚C 38.2 kΩ
40 ˚C 25.4 kΩ
50 ˚C 17.2 kΩ
60 ˚C 11.8 kΩ
70 ˚C 8.3 kΩ
80 ˚C 6 kΩ
85 ˚C 4 kΩ
Regeneration on appliances without
potentiometer for water hardness
Volume 300 cm
3
after wash cycles 1
water hardness 0 - 60 ˚dh
0 - 10.7 mmol/l
0 - 107 ˚Fh
Salt consumption
for regeneration 77 g
Number of cycles
with 2 kg salt 26
Accesory
If you need spare parts apart from
the spare part list have a look
in the Service Bulletin 4812 718 40084.