EasyManua.ls Logo

Whirlpool LCE4332PQ - Removing Actuator and Drain Pump

Whirlpool LCE4332PQ
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-16
REMOVING THE BRAKE ACTUATOR ASSEMBLY
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
WARNING
1. Unplug washer or disconnect power.
2. Turn off the water supply to the washer.
3. Tape the lid closed and lay the washer on
its rear panel so that you can access the
bottom of the unit.
Brake Actuator
5. Disconnect the two wire connectors from
the brake actuator terminals.
6. Remove the two phillips brake actuator
screws from the motor support.
4. Remove the capacitor clamp screw, and
remove the capacitor and clamp from the
motor support (see the photo at the top of
the right column). NOTE: Allow the ca-
pacitor to hang by its wires out of the way.
Capacitor
Clamp Screw
Actuator Wire
Connectors
Actuator
Screws
Brake Actuator