Gas and Electric Dryer
PRODUCT MODEL NUMBERS
W10848818A
01/18
WED4950HW, WGD4950HW, WED4850HW,
WGD4850HW, YWED4850HW
Installation clearances:
For each arrangement, consider allowing more space for ease of
installation and servicing, spacing for companion appliances, and
clearances for walls, doors, and oor moldings. Space must be
large enough to allow door to fully open. Add spacing on all sides
of dryer to reduce noise transfer. If a closet door or louvered door
is installed, top and bottom air openings in door are required.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
Dryer Dimensions
Front View
50
3
/4"
(1289 mm)
42"
(1067 mm)
28
1
/4"
(717 mm)
28
1
/4"
(717 mm)
NOTE: Minimum height of leveling legs should be 1/2" (13 mm),
or high enough for dryer to match the height of the accompanying
washer.
Side View
29"
(737 mm)
40
7
/8"
(1038 mm)
1
/2"
(13 mm)
A B
A. Wide opening side-swing door
B. Wide opening hamper door
Back View
14
1
/
2
"
(368 mm)
4
3
/4"
(121 mm)
9
1
/4"
(235 mm)
1
1
/4"
(32 mm)
14
1
/
2
"
(368 mm)
4
3
/4"
(121 mm)
9
1
/4"
(235 mm)
1
1
/4"
(32 mm)
30
1
/4"
(768 mm)
4"
(101 mm)
Non-Steam
Installation spacing for recessed area
or closet
The dimensions shown are for the minimum spacing allowed.
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door,
and oor moldings.
Additional spacing of 1" (25 mm) on all sides of the dryer
is recommended to reduce noise transfer.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
Companion appliance spacing should also be considered.
Installation Spacing
6"/0"
(152 mm/
0 mm)
14" max
(356 mm)
1"/0"
(25 mm/0 mm)
1"/1"
(25 mm/25 mm)
18"/18"
(457 mm/
457 mm)
3"/3"
(76 mm/
76mm)
3"/3"
(76 mm/
76mm)
48"
2
/48"
2
(310 cm
2/
310 cm
2
)
24"
2/
24"
2
(155 cm
2/
155 cm
2
)
Recommended/Minimum spacing
Steam

Questions and Answers:

Whirlpool WGD4950HW Specifications

General IconGeneral
BrandWhirlpool
ModelWGD4950HW
CategoryDryer
LanguageEnglish

Summary

Installation Clearances and Dimensions

Dryer Unit Dimensions

Details front, back, and side view dimensions of the dryer unit for installation planning.

Installation Spacing Requirements

Provides minimum and recommended spacing for recessed areas, closets, and general installation.

Installation Requirements

Gas Supply Requirements

Details natural gas and L.P. gas connection requirements, including pipe size and shut-off valve.

Electrical Requirements

Specifies electrical supply needs for gas and electric models, including voltage and circuit type.

Water Requirements (Steam Models)

Covers cold water faucet connection, pressure, and hose requirements for steam models.

Venting Requirements Overview

Explains essential outdoor venting rules, materials, and safety warnings to prevent fire.

Vent System Chart Guidance

Provides chart for acceptable vent types, lengths, and elbows for optimal drying performance.

Related product manuals