ELECTRICAL REQUIREMENTS
Before you move your upright freezer into its final location, it is important to make sure you have the
proper electrical connection:
A standard electrical supply (115V, 60Hz, 10A), properly grounded in accordance with the
National Electrical Code and local codes and ordinances, is required.
It is recommended that a separate circuit, serving only your upright freezer, be provided. Use
receptacles that cannot be turned off by a switch or pull chain.
The fuse (or circuit breaker) size should be 10 amps.
Recommended grounding method
For your personal safety, this appliance must be grounded. It is equipped with a power supply cord
having a 3-prong grounding plug. To minimize possible shock hazard, the cord must be plugged into a
mating 3-pronged and grounding-type wall receptacle, grounded in accordance with the National
Electrical Code and local codes and ordinances.
Technical Information
Voltage 115V
Frequency 60Hz
Input Power 75W
Refrigerant R134a, 2.29g
Unit Temperature Range -10° - 2°F
Operating Temperature Range 60 - 85°F
Rated Current 0.88A
Volume 2.1 cu. ft.
Weight 44 lbs.
Unit Dimensions 27.5” H x 17.5” W x 20.1” D
Control Type Mechanical
Defrost Type Manual
Lock Yes
Cabinet Shelves (Total) 2
NOTE: Technical data and performance information provided for reference only. Specifications are
subject to change. Check the rating label on the upright freezer for the most accurate information.
Electrical Shock Hazard
Plug into a grounded 3-prong outlet.
Never remove the grounding prong from the plug.
We strongly recommend against the use of an extension cord. However, if
you must use an extension cord, it is absolutely necessary that it be a
UL-listed 3-wire grounding type appliance extension cord having a grounding
type plug and outlet and that the electrical rating of the cord be 15 amperes
(minimum) and 120 volts.
Failure to follow these instructions can result in fire, electrical shock, or death.