Operating instructions bypass level indicator, model BNA
8.2 Return
Wash or clean the dismounted bypass level indicator before returning
it, in order to protect personnel and the environment from exposure to
residual media.
Information on returns can be found under the heading
“Service” on our local website.
8.3 Disposal
Incorrect disposal can put the environment at risk.
Dispose of instrument components and packaging materials in an
environmentally compatible way and in accordance with the country-
specic waste disposal regulations.
9. Specications
Bypass level
indicator
Material Max.
pressure
in bar
Max.
temperature
in °C
Compact version,
model BNA-C
Stainless steel 1.4571
(316Ti)
40 -196 ... +150
Standard version,
model BNA-S
Stainless steel 1.4571
(316Ti), 1.4404 (316L),
1.4401/1.4404 (316/316L)
64 -196 ... +450
High-pressure
version,
model BNA-H
Stainless steel 1.4571
(316Ti), 1.4404 (316L)
400 -196 ... +450
Plastic version,
model BNA-P
PP, PVDF 6 -10 ... +100
DUPlus version,
standard,
model BNA-SD
Stainless steel 1.4571
(316Ti), 1.4404 (316L),
1.4401/1.4404 (316/316L)
64 -196 ... +450
DUPlus version,
high pressure,
model BNA-HD
Stainless steel 1.4571
(316Ti), 1.4404 (316L),
1.4401/1.4404 (316/316L)
160 -196 ... +450
8.Dismounting,returnand.../9.Specications