Please read the Operating Instructions before using the cabinet.
The Williams range of Blast Chillers has temperature parameters set as follows:
+70°C (158°F) / +3°C (38°F).
The Williams range of Blast Chiller Freezers has temperature parameters set as follows:
+70°C (158°F) /+3°C (38°F) and +70°C (158°F) / -18°C (0°F).
OLD CABINETS
Please ensure the old / redundant cabinet and refrigeration equipment are disposed of safely and
legally. We would recommend that any doors are removed prior to disposal to ensure safety.
UNPACKING
Remove all the external and interior packing from the cabinet and accessories. Please ensure all packaging is
disposed of safely.
MAINS CONNECTION
All models (except WBC/WBCF50) are single phase and come fitted with moulded plug for safety and must be
earthed. We recommend that should the plug or cable fail contact Williams spares office for a replacement part.
The WBC/WBCF50 is supplied with a 3m 5-core cable (each core 1.5mm thick) to be wired directly into
3 phase power supply. The wiring should be carried out by an qualified refrigeration engineer or electrician.
INSTALLATION
The cabinet should stand level to ensure correct operation of self closing doors and proper drainage of
condensate from the evaporator. All models (except WBC/WBCF50) feature automatic evaporation so no
drain is required.
Models fitted with castors are non adjustable, therefore a level platform/floor should be provided where the
cabinet is to be located. On models fitted with adjustable legs levelling may be achieved by adjustment of the
bottom section of the legs. For marine specification models with flanged feet for deck fixing and bulkhead
fixings, installation should be carried out by a specialist marine companies.
For top mounted refrigeration systems (WBC50) please ensure there is 500mm between the top of the cabinet
and ceiling for engineer access and ventilation.
If the cabinet has been laid on its back or tipped, DO NOT switch on immediately. Leave the cabinet in the
upright position for at least 1 hour before switching on.
Before loading, allow the cabinet to reach its normal operating temperature.
NB: WBC/WBCF50 requires the condensate drain pipe to be connected to a suitable 22mm (7/8”) waste
pipe or larger with ‘P’ trap or routing to an open floor drain. (This can be found at the base of the
cabinet rear).
Locking Castors
When the cabinet has been positioned please ensure brakes have been activated by pressing the metal bar
down. Remember to release the brakes before trying to move the cabinet.
Shelf/Slide Fitting
When positioning the slides present the slide to the racking by holding it in the opposite hand to the side of the
cabinet you are installing the slides. Offer the slide at a 45° angle as shown in figure 1. Once in place let slide
drop into position creating a horizontal ledge on which the shelves will sit.

Other manuals for Williams WBCF50