INSTALLATION
8
8
9
1
4
3
5
7
6
2
1
6
-. Close the discharge valve(2) and open the Pressure Tank(4).
-. Open the suction valve(1) to fill the pump with water.
If don’t fill water in pump, please open the air vent screw(3).
-. Close the air hopper cap(3) and the Pressure Tank(4)
when water comes out from the air vet screw.
-. Open the discharge valve(2) after turning on the pump.
1. Stop valve on the
s
uction side
2. Stop valve on the
discharge side
3
. Hopper cap
4. Pressure Tank
5
. Drain screw
6. Pipe support
7. Strainer
8. Water tank
9. Piping
Part Description