8. Fault Findings
Causes and Remedies
8.1 Pump is switched on, but
fails to run:
Check power supply fuses.
Check voltage at pump terminals
(refer to name plate data).
Check capacitor size (refer to name
plate data!).
Rotor shaft has jammed, e.g. by
incrustations.
Remedy: Remove central access
plug, check free movement of shaft
or free respectively at the slotted
shaft end by means of a screw-
driver.
Observe safety procedures
as for 6.1!
At high water temperatures
and system pressures, close
isolating valves at both pump
ports. First, allow pump to
cool down.
8.2 Noise
Cavitation due to insufficient inlet
pressure.
Remedy: Increase system pressure
within permissible limits.
If the fault cannot be located or rec-
tified, please contact your nearest
Wilo representative.
9. Spare Parts
State all name plate data when order-
ing spare parts.
Technical modifications reserved.