Overload protection
The pump disposes of an integrated overload protection. After being switched of by the overheating
protection, the pump has to cool down for a while before re-operation. If it does not start re-operating
by itself the following checks are to be performed:
Could the pump cool down sufficiently after the switch-off by the overheating protection
Is there a sufficient water supply? > Improve water supply!
Is there any dirt in the pump housing? > Cleaning as below mentioned!
Hose or tube clogged? > Clean!
Hose bend or to long? > Check, replace, cut it!
Model Voltage
Perfo
r-
mance
Flow Rate
Delivery head
Connection
(inch)
Cord length
CTF
-
2800
AC 220-240V/50Hz
10W
3000 l/h
2 m
1“ – 1 ¼“ –1½“
10 m
CTF
-
3800
20W
3600 l/h
2.8 m
1“ – 1 ¼“ –1½“
10 m
CTF
-
4800
30W
4500 l/h
4 m
1“ – 1 ¼“ –1½“
10 m
CTF
-
5800
40W
5200 l/h
4.8 m
1“ – 1 ¼“ –1½“
10 m
CTF
-
5000
30W
5000 l/h
3.3 m
1“ – 1 ¼“ –1½“
10 m
CTF
-
6000
40W
6000 l/h
4.2 m
1“ – 1 ¼“ –1½“
10 m
CTF
-
7000
50W
7000 l/h
4.6 m
1“ – 1 ¼“ –1½“-2
10 m
CTF
-
8000
70W
8000 l/h
5.6 m
1“ – 1 ¼“ –1½“-2
10 m
CTF
-
10000
80W
10000 l/h
6 m
1“ – 1 ¼“ –1½“-2
10 m
CTF
-
12000
100W
12000 l/h
6.5 m
1“ – 1 ¼“ –1½“-2
10 m
CTF
-
14000
120W
14000 l/h
7 m
1“ – 1 ¼“ –1½“-2
10 m
CTF
-
16000
140W
16000 l/h
7.5 m
1“ – 1 ¼“ –1½“-2
10 m
Maintenance
The pond motor pump is a proven quality product subjected to strict final instructions.
However, in order to ensure a long durability and a continuous operation, we recommend a regular
control and and care.
To ensure the proper operation of the pump it is indispensable to clean it regularly. We advise a
weekly cleaning. Kindly remove the pump housing and clean the pump with a smooth brush in running
water. Remove any residue found on the pump shaft.
Winter storage
5. Remove the pump from the water and disconnect it from the power supply.
6. Clean the pump as afore mentioned.
7. Check the pump with regard to damage, such as cracks or cuts in the housing.
8. Kindly store the pump under frost-free conditions, if possible in a container filled with water.