© by WilTec Wildanger Technik GmbH Item 50610, 51246 Page 5
http://www.WilTec.de
http://www.aoyue.eu 09 2021-1
http://www.teichtip.de
Notes on installation
We recommend connecting the pump
control to the house water pipe via a
flexible hose.
Safety valve to pre-
vent water leakage if
the diaphragm
bursts (do not work
on or change!).
The control must be
oriented upwards ac-
cording to the direction
of the arrow.
The controller can be in-
stalled directly on the pump
or between the pump and
the first tapping point.
Before the
start of the ma-
chine, the suc-
tion hose and
pump filling
must be
checked!
Do not place any extraction
points between the pump and
switch.
The machine is
equipped with a test
valve to protect the pip-
ing system from pres-
sure loss.
If the water column be-
tween the pump and the
highest point of the pipe
exceeds 15 m, the au-
tomat cannot be in-
stalled directly at the
pump. The machine
must then be installed
at a height where the
overhanging water col-
umn is shorter than
15 m. For example: If
the water column is
20 m, the machine must
be installed at least 5 m
above the pump.

Related product manuals