Operating Instructions (ENG)
MODELS: RMBS12 BEFORE S/N12236
RMBS16 BEFORE S/N 16905
Read instructions before operating the machine.
J
980124 09/20/05

Questions and Answers

  • H
    Haley RossJul 31, 2025
    Why Windsor ROMBUS RMBS12 has no power?
    • B
      briana46Jul 31, 2025
      If your Windsor Vacuum Cleaner isn't receiving power, there are several potential causes. It could be due to a dead electrical circuit breaker in the fuse box, in which case you should check the building's circuit breaker. Alternatively, there might be a faulty power cord, requiring a replacement. Another possibility is a power switch failure, which would also necessitate replacement. A faulty circuit breaker could also be the cause, and it would need to be replaced. Finally, an internal wiring problem could be the culprit; with the machine unplugged, check for and correct any loose wire connections.
  • J
    Jason ShawAug 7, 2025
    How to fix Windsor ROMBUS RMBS12 Vacuum Cleaner brush not turning?
    • M
      Michelle WestAug 8, 2025
      If the brush on your Windsor Vacuum Cleaner isn't turning or scrubbing, potential causes include a faulty brush motor (replace the brush motor), worn gears (replace the gears that are not functioning), worn brushes (replace the brushes), or worn brush motor brushes (replace the brushes and check the commutator).
  • E
    ecrossAug 15, 2025
    What to do if Windsor Vacuum Cleaner causes electrical shock?
    • M
      Megan YoungAug 15, 2025
      If you're experiencing electrical shocks from your Windsor Vacuum Cleaner, it could be due to several reasons. The equipment might not be properly grounded; ensure you follow the grounding instructions. Another cause could be a receptacle that isn't grounded; in this case, have an electrician inspect the building's wiring. Finally, there might be an internal electrical problem; check for any loose wire connections and replace any items that are short circuiting.
  • M
    mcbridedianaAug 23, 2025
    Why does my Windsor ROMBUS RMBS12 Vacuum Cleaner circuit breaker keep tripping?
    • C
      Christian MartinezAug 23, 2025
      Nuisance tripping of the circuit breaker in your Windsor Vacuum Cleaner may be due to a faulty circuit breaker, which would need to be replaced. Alternatively, a mechanical problem could be the cause. Test the circuit breaker for continuity; a higher amp draw may indicate faulty parts. Find parts not moving freely and repair or replace them.

Summary

Overview of Windsor Rombus Carpet Maintainer

How to Use This Manual

Important Safety Instructions

Hazard Intensity Level Definitions

Grounding Instructions

Technical Specifications

How the Machine Works

Machine Operation Procedures

Pre-Run Machine Inspection

Perform pre-operation checks to identify potential problems and confirm specifications.

Starting the Machine

Steps for connecting, releasing handle lock, and engaging the foot switch to start.

Machine Shut-down and Storage

Procedures for powering off, locking the handle, disconnecting power, and storing the machine.

Maintenance Schedule and Procedures

Brush Cleaning and Maintenance

Instructions for cleaning brushes and brush housing after use.

General Machine Maintenance

Guidance on keeping the machine clean and ensuring air vents are clear.

Daily Maintenance Tasks

Routine checks including brushes, housing, and power cord inspection.

Periodic Maintenance Tasks

Regular checks of controls, cables, connections, brushes, and brush guard.

Annual Maintenance Tasks

Yearly checks for bearings, motor operation, and overall machine function.

Machine Troubleshooting Guide

Windsor ROMBUS RMBS12 Specifications

General IconGeneral
BrandWindsor
ModelROMBUS RMBS12
CategoryVacuum Cleaner
LanguageEnglish

Related product manuals