10
English
50BT, 70BT
②
Remove the bucket from the unit. Remove the DRAIN CONNECTOR from
the bucket.
③
Install the DRAIN CONNECTOR to the
dehumidifier by inserting fully into
the gravity drain in the rear of the unit,
and turning clockwise.
④
Screw a standard drain hose to
the drain connector by turning
it clockwise.
OPERATION
Defrost Operation
x
The dehumidier has a built-in defrost control that senses frost buildup on
the evaporator coils.
x
During defrosting, the compressor will automatically turn o; the fan will
continue running to defrost the coils.
Automatic Shut off
x
When the bucket is full, or when the bucket is not in the proper position,
the Bucket Full light will turn on and the unit will automatically shut o.
x
The unit will automatically shut o when the bucket is not seated properly
in the unit. The light will stay on until it is adjusted properly.
x
The unit will turn o once the set humidity level is reached, plus or minus
5% Relative Humidity (RH).