EasyManua.ls Logo

Wolfgang Warmbier PGT 2000 User Manual

Wolfgang Warmbier PGT 2000
4 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Technical Information
Page1of4
Part No.: 7100.PGT2000.NET
Untere Gießwiesen 21 78247 Hilzingen Tel.: +49-7731-86880 Fax: +49-7731-868830
We believe all the information in these pages including technical data to be reliable. However we make no warranties
expressed or implied and assume no liability regarding any use of this information.
V0102
PGT 2000 Personnel Grounding Tester
(Part No.: 7100.PGT2000.NET )
Measures personnel grounding including user`s identification and test values documentation
(required by DIN ISO 9000 for example).
Simultaneous measurement of wrist strap and footwear according to DIN EN 61340-5-1
Measurement takes < 1,5 sec for personnel identification, wrist strap and footwear tests
Separate right and left foot test values
Transponder personnel identification system
Access control of protected zones and EPA's through the door opener
Audible and visible test signal
Progammable test voltage and resistance values
Configuration and data transfer through the RS232 port or the Ethernet network card
Integral memory for saving personnel data and test values
(20.000 test values and 5.000 personnel records)
Network connection of up to 64 instruments
Including operating software, MS-Windows® 95/98/NT/2000 compatible, PGT 2000 Manager
Includes:
PGT built-in network card, shoe-testing electrode, wall mounting plate, external power supply 230
VAC, RS 232 null modem cable, CD-ROM “PGT 2000 Manager” installation program, user`s manual
in English and German and a calibration certificate.
Unit description:
Display
wrist strap test
LED indicator
upper limit exceeded
LED indicator
below low limit
Male snap 3mm
Keyboard for
special function
LED indicator
identification failed
Display
wrist strap connector Button for
wrist strap test
Button for
footwear test
footwear test
LED indicator
upper limit exceeded
LED indicator
below low limit
LED indicator
measurement value
in the limit
Dimension:
180 x 264 x 100 mm
Question and Answer IconNeed help?

Do you have a question about the Wolfgang Warmbier PGT 2000 and is the answer not in the manual?

Wolfgang Warmbier PGT 2000 Specifications

General IconGeneral
BrandWolfgang Warmbier
ModelPGT 2000
CategoryTest Equipment
LanguageEnglish

Summary

PGT 2000 Personnel Grounding Tester

Product Features and Functionality

Simultaneous wrist strap/footwear testing, user ID, access control, data transfer, and memory storage.

Included Components

Lists PGT network card, electrodes, power supply, software, manuals, and calibration certificate.

Unit Overview

Description of the PGT 2000 unit, display, controls, and indicators for tests.

Hardware Connectivity and Components

Plug-in Options

Details the available sockets for connecting electrodes, door opener, Ethernet, power, and PC.

Identification System

Describes footwear and wrist strap transponders, including bags and dimensions.

Footwear Electrode

Details the separate shoe measurement electrode with built-in antenna.

Configuration and User Management

Device Configuration

Setting limit values and test voltages within ESD-standard defined limits for up to 64 devices.

User Database Management

Managing users, assigning transponders, and defining access permissions via user profiles.

Test Data and Reporting

Test Report Overview

Summary of test results including personnel, shoe, and hand grounding measurements.

Data Export

Information on printing and exporting test values in different file formats.

Related product manuals