Page 5
www.wolverineairsoft.com
STORM OnTank/HighPressure
Installation
To install the regulator, simply thread the
regulator onto the top of your HPA tank.
Screw the regulator all the way down until
it stops. The final ½-¾ turn will open valve
on the tank regulator to pressurize the
system.
Removal
To remove the regulator, unscrew the
regulator one complete turn from the tank.
Fire the gun to vent any pressure past the
regulator. Completely remove the regulator
from the tank. Do not partially unscrew
the regulator and then re-tighten it without
completely removing the regulator from the
tank as it may pinch your tank O-ring.
Tuning
Adjust the pressure on the tank by using
the included 3/32 hex key to turn the small
set screw on the front of the regulator. The
regulator is not self-venting so you will need
to have the gun connected and fire the gun
when adjusting the pressure lower before
the gauge will show the new pressure.
Tournament Lock
To engage the tournament lock, slide the
black sleeve down to cover the pressure
adustment set screw. Then, simply secure
the sleeve with a zip tie.
Decrease
pressure
Increase
pressure