Troubleshooting
Setworks Malfunction
3
3-2 SW-10doc032018 Troubleshooting
Setworks stops the saw head
and ’’Err PULS” appears on
the display.
Blade height sensor signal is
bad.
- Check the connections between
the blade height sensor and the
controller.
- Check if the encoder or the
magnetic strip (depending on the
machine) is not loose.
- Check condition of the encoder
coupling (LT15 sawmills only).
- Check if the connections to the
sawmill up/down system
contactors are correct and not
loose.
During manual downward
head movement, the upper
display shows a negative
blade height value.
Setworks not calibrated Perform the auto-calibration
procedure.
When pressing
during normal operation or
when attemting to save the
program (using
button), the upper display
shows horizontal dashes.
The lower blade height limit
would be exceeded if the
requested saw head
movement was performed.
Try to enter a lower board
thickness value.
During manual controlling of
the head height, the display
shows:
Real blade height incorrectly
entered
Enter the real distance between
the blade and the bed rails. See
Section Entering Real Blade
Height Dimensions.
Perform the auto-calibration
procedure.