Questions and Answers

  • J
    Jason BerryAug 7, 2025
    How to fix a Woodpecker Fi-G device that won't turn on?
    • J
      Jonathan AndersenAug 8, 2025
      If your Woodpecker Medical Equipment device doesn't turn on after pressing the power button, there might be a few reasons. First, the battery may be low, so connect it to a power supply to charge. Another possibility is a damaged battery, which would need replacement. If the charging interface is short-circuited, remove the cause of the short circuit and place the device on the charging base. If none of these steps work, the device itself may be damaged, and you should contact your local distributor or the manufacturer.
  • K
    Katrina SwansonAug 12, 2025
    What to do if my Woodpecker Fi-G is not charging?
    • M
      Melissa ChavezAug 12, 2025
      If your Woodpecker Medical Equipment fails to charge after connecting it to the power supply, first, ensure the power supply is correctly connected by unplugging and reconnecting it. If the issue persists, the power supply might be damaged or doesn't match the device's specifications, requiring a replacement. Also, check the charging base for impurities on the contact thimble; if present, wipe it with alcohol, let it dry, and then reconnect the device.
  • D
    David YatesAug 16, 2025
    Why won't gutta-percha come out of my Woodpecker Fi-G needle?
    • W
      William GrahamAug 16, 2025
      If gutta-percha isn't flowing from the needle of your Woodpecker Medical Equipment, it could be due to several reasons. The gutta-percha stick may have run out, so pull back the pushing ram and load a new one. Another cause might be a damaged pushing ram seal ring, which would need replacing. Finally, the injection needle itself might be damaged or blocked, requiring a replacement.
  • K
    Karen PetersAug 20, 2025
    Why does my Woodpecker Medical Equipment shut down automatically?
    • L
      larsonhenryAug 20, 2025
      Your Woodpecker Medical Equipment is designed to automatically power off if there is no operation for 10 minutes. To continue using the device, simply reboot it.
  • D
    dhurstAug 25, 2025
    How to remove a stuck pushing ram from Woodpecker Medical Equipment?
    • K
      kathleenjonesAug 26, 2025
      If the pushing ram of your Woodpecker Medical Equipment is stuck, it may be fixed in place by cooled gutta-percha. To resolve this, power on the device and set the temperature to 200 °C. Once the device reaches this temperature, you should be able to pull the pushing ram back.
  • R
    Robert BanksAug 28, 2025
    Why is the service time after charging my Woodpecker Fi-G Medical Equipment shortened?
    • C
      Courtney MooneyAug 29, 2025
      If the service time of your Woodpecker Medical Equipment is reduced after each charge, it indicates that the battery capacity has diminished. In this case, you should send the device to a repair center.
  • C
    Carmen FletcherSep 2, 2025
    What does it mean if an ERROR code appears on my Woodpecker Medical Equipment display?
    • K
      Keith AlexanderSep 2, 2025
      If an ERROR code appears on the display screen of your Woodpecker Medical Equipment, it suggests that the heating chamber is damaged. You should send the device to the repair center.