EasyManuals Logo

Worcester 35CDi User Manual

Worcester 35CDi
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #28 background imageLoading...
Page #28 background image
Supplied By www.heating spares.co Tel. 0161 620 6677
28
Above
9°C
Commence normal
central heating mode
until temperature
reaches 30°C
5°C
to
9°C
Below
5°C
No demand
and primary
temperature
below 8°C
Internal
“Autofrostat”
demand
Wait in normal
off state for
30 minutes
Run pump for
four minutes
Monitor
central
heating
sensor
Return to
normal off
state
AUTOFROSTAT FUNCTION
Within four
minutes of last
hot water
demand
AND
primary
temperature
above 80°C
If heat
demand has
occured in last
30 minutes
Run pump
until primary
drops to
80°C
If heat
demand has
NOT
occured in last
30 minutes
Run pump
until primary
drops to
80°C
If primary
temperature
still increases
above 90° C
Run pump for
2 seconds
OVERRUN FUNCTION
AUTOFROSTSTAT FUNCTION

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Worcester 35CDi and is the answer not in the manual?

Worcester 35CDi Specifications

General IconGeneral
Model35CDi
Output35kW
ERP RatingA
Domestic Hot Water Output35kW
Max Working Pressure3 bar
Fuel TypeNatural Gas