EasyManua.ls Logo

Worcester zwbr 11-42 rd 542i combi

Worcester zwbr 11-42 rd 542i combi
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Supplied By www.heating spares.co Tel. 0161 620 6677
7 181 465 347 (05.01)
20
Rectifying faults
Error A8
A8 flashing.
No correct electrical connection
Check Action
1. B Power OFF the appliance.
B Check Wiring between Textdis-
play and TR 2:
Terminal 3 on Textdisplay con-
nected to Terminal 3 TR 2?
Terminal 4 ...Terminal 4
Terminal F ...Terminal F?
yes: 2.
no: B Rewire correctly as specified in the installation
instructions.
B Turn ON the appliance.
After 90 sec.:
A8?
B Power OFF the appliance.
2.
2. B Check continuity on wiring to TR 2.
Is there continuity?
yes: 3.
no: B Replace or repair wiring and/or connections.
B Turn ON the appliance.
After 90 sec.:
A8?
B Power OFF the appliance.
3.
3. B Check resistance from connections
4 to F and 3 to 4.
Is resistance between XX and XX?
yes: B Replace TR 2.
no: 4.
4. The PCB control board is damaged. B Make a note of the altered service function set-
tings (see table 1 on page 7) in order to keep
the altered values.
B Power OFF the appliance.
B Disconnect the boiler electrical connection.
B Change PCB control board.
B Reconnect the boiler electrical connection.
B Turn ON the appliance.
B Restore service settings previously noted down.