Rectifying faults
Error EA
10.
Is flue gas CO
2
level incorrect
1)
?
yes: B Adjust to correct level.
B Press , restart the appliance.
EA? ↓11.
no: ↓11.
11. B Activate menu option Show service
parameters.
B Select 5.1 Permanent ignition
(without Gas).
Continuous ignition (without gas) OK?
yes:
B Press button to select no.
↓12.
no:
B Press button to select no.
↓15.
12. Ignition lead connected to ignition elec-
trodes?
yes: ↓13.
no: B Reconnect lead.
B Press , restart the appliance.
EA? ↓13.
13. Ignition cable connector engaged in
switchbox?
yes: ↓14.
no: B Power OFF the appliance.
B Engage ignition cable connector in switchbox.
B Turn ON the appliance.
B Press , restart the appliance.
EA? ↓14.
14. Is the ignition electrical wire
damaged?
yes: B Power OFF the appliance.
B Change the ignition electrical wire.
B Turn ON the appliance.
B Press , restart the appliance.
EA? ↓15.
no: ↓15.
15. B Activate menu option Show service
parameters.
B Select 3.3 Ionisation current .
Measured ionisation current medium
or high?
yes: ↓17.
no: ↓16.
16. Electrode assembly defective?
B Power OFF the appliance.
B Remove electrode assembly.
Electrode assembly burnt out?
yes: B Replace electrode assembly.
B Turn ON the appliance.
B Press , restart the appliance.
EA? ↓17.
no: B Refit electrode assembly.
B Turn ON the appliance.
B Press , restart the appliance.
EA? ↓17.
EA and flashing.
During operation: flame not detected
Check Action