The WPM Welhome Pro MS-130T is a professional milk steamer designed for efficient and continuous steam generation, suitable for both household and commercial applications.
Function Description
The primary function of the MS-130T is to steam milk for various beverages. It features a high-efficiency heating system and a powerful pressure pump to generate consistent and strong steam. The device allows users to set and adjust the target milk temperature, and it automatically stops steam dispensing once the desired temperature is reached. It also includes a cleaning function to maintain hygiene and prevent blockages.
Important Technical Specifications
- Product Name: Milk Steamer
- Product Model: MS-130T
- Voltage and Power: 220V-240V~50-60Hz, 1450W-1720W
- Pressure Pump: 4 bar / 0.4 MPa for generating 1.5 bar / 0.15 MPa steam.
- Temperature Setting Range: 40°C - 90°C (104°F - 194°F)
- Maximum Steam Release Time: 4 minutes (automatic shut-off if target temperature is not reached within this time).
- Room Temperature Range for Operation: 10°C - 32°C (50°F - 90°F)
Usage Features
The MS-130T is designed for user-friendly operation with a clear control panel and display.
Control Panel Components:
- Display: Shows current status, temperature, and preheating indicators.
- Steam Button: Initiates steam dispensing.
- Clean / Flushing Button: Activates the cleaning cycle for the steam wand.
- Pre-set Menu Buttons (P1, P2): Used to access and save preset temperatures.
- Temperature Adjustment Buttons (Up/Down arrows): Adjusts the target temperature.
Operational Steps:
- Power On: Switch on the main power button located on the left lower side of the machine.
- Preheating: The display will show "---" during preheating. Once ready, it will show the previously set target temperature.
- Temperature Setting:
- Preset Menu: Press and hold P1 or P2 to view and adjust preset temperatures. Use the up/down arrows to change the temperature and release the button to save (indicated by three beeps).
- Normal Target Temperature: Use the up/down arrows directly to adjust the target temperature.
- Start Milk Frothing:
- Set the desired target temperature.
- Press the steam button to begin frothing. The display will show the rising liquid temperature.
- The machine automatically stops steam dispensing when the target temperature is reached.
- Steam dispensing can be manually stopped by pressing the steam button again.
- After Frothing: The machine returns to ready mode, displaying the previous target temperature.
Safety Precautions during Use:
- Ensure the unit is on a firm, flat surface.
- Never immerse the appliance in water or other liquids.
- Do not operate with an empty water tank; fill only with room temperature water.
- Avoid direct sunlight.
- Do not touch the hot steam wand directly after operation.
- Turn off and unplug the appliance when not in use or unattended.
- Keep the power cord away from hot surfaces and table edges to prevent tripping.
- Do not operate without load to avoid damaging heating elements.
- Do not place hands under the steam nozzle directly due to scalding risk.
- Use a suitable power source (220-240V~/50Hz).
- Never leave the appliance unattended while in use.
- Do not remove the steam wand from liquid before it completely shuts down.
- Avoid spillage on the connector.
- Potential injury from misuse is a warning.
Maintenance Features
Regular cleaning and maintenance are crucial for the longevity and optimal performance of the MS-130T.
Daily Cleaning (Every Single Use):
- Clean After Use: Press the clean/flushing button to dispense steam for 6 seconds, cleaning milk residue inside the steam wand.
- Wipe Steam Wand: Immediately wipe the steam wand clean with a damp cloth to remove milk residue from its surface.
- ATTENTION: Users MUST flush the machine after each use to prevent blockage of the steam wand.
- WARNING: The surfaces are liable to get hot during use.
Weekly Cleaning (After 1 Week Usage):
- Descaling: A descaling agent should be applied. Follow the instructions provided with the descaling agent.
- Cleaning Mode:
- Ensure the water tank is filled.
- Place a heat-resistant large container below the steam nozzle.
- Press and hold the clean/flushing button for 3 seconds to enter cleaning mode (display shows "CL").
- Press the steam button to start the rhythmic hot water dispensing program.
- The program stops when the water tank is empty (display shows "FILL").
- Refill water to continue cleaning or press and hold the clean/flushing button for 3 seconds to exit cleaning mode.
- The machine will restart automatically for next use.
- REMINDER: Ensure all cleaning agents are consumed after cleaning.
- WARNING: Be careful of burns; hot water temperature during cleaning is 40°C - 60°C.
- ATTENTION: Never clean the steam wand with an abrasive pad as this will damage it.
General Maintenance Guidelines:
- Clean the surface of the appliance with a dry cloth; do not use corrosive detergents or solvents, and do not wash with water.
- Turn off and unplug the appliance when not in use, especially for prolonged periods. Store in a dry, cool place.
- Avoid placing flammable or explosive objects near the appliance.
- Do not install in rooms cleaned with water jets, and do not clean the machine with water jets.
- Operation and maintenance should only be performed by trained personnel.
- Any malfunction, including power cord issues, requires immediate cessation of use and repair by an authorized service center. Do not attempt self-repair.
Maintenance Terms (Situations Not Accepted):
- Formation of scale in the thermoblock due to not using distilled water or inadequate/irregular cleaning.
- Blocking in the steam wand due to inadequate/irregular cleaning.
Recycling and Disposal:
- Packaging: The packaging materials are recyclable. Return packaging into the material cycle to save raw materials and reduce waste.
- Unit Disposal: At the end of its service life, the product should not be disposed of with normal domestic waste. The symbol on the product and in the manual indicates its recyclability. Contact your municipal administration for disposal points.